ZXBAR 27 Pressure Transmitter-Hygenic Type
The ZAXBAR 2x series intelligent pressure transmitters adopted diffused silicon pressure core which allow for 0.2% accuracy,it is matured technology combine with cost-effective solution for pressure measurement. Pressure range can up to 100MPa. Standard 4-20mA HART or RS485 output, you can integrated to your PLC system easily.
Pending Update
Pending Update
- Application
- Gas
- Vapour
- Liquid
- Diaphragm Material
SS316L
- Process connection
SS304
- SS316L
- Enclosure
Aluminum Alloy
- Sealing Material
Nitrile Rubber
- Pressure Range
-100kPa to 0 to 100MPa
- Pressure mode
Gauge Pressure
Absolute Pressure
Negative Pressure
- Output
4-20mA
- 4-20mA HART
RS485 Modbus-RTU
0-10V DC
0-5V DC
1-5VDC
- Power Supply
8-30VDC (conventional)
24VDC (explosion-proof type/dust-proof explosion-proof type)
- 12-30VDC (conventional (with display or output 0-10VDC)
- Accuracy
- 0.2%FS Calib Range ≥ 100kPa
- 0.5%FS (10kPa ≤ range < 100kPa, default)
1%FS (range < 10kPa, default)
- Medium Temperature
-40 to 85℃
- Environmental Humidity
0% to 95%RH (no condensation, no dew formation)
- Environmental Temperature
-40 to 85℃ Standard
-20 to 40℃ Flameproof
- Temperature Compensation
-10 to 70℃ (precision 0.25%FS, 0.5%FS, 1%FS)
-40 to 80℃ (precision 0.1%FS)
- Explosion Proof
Flameproof :Ex d Ⅱ CT6 Gb
Intrinsically Safe: Ex ia ⅡCT6 Ga (limited current output)
Dust-proof : Ex iaD 20 T80℃ (limited current output)
Note: Intrinsically Safe must be powered by safety barrier or IS power supply.
- Overload
200% full scale or 120 MPa (take the lesser value)
- Response Frequency
Analog signal output 10 – 2400 Hz
Digital signal output 10 Hz
- Stability
± 0.1% FS per year
- Temperature Drift
± 0.01% FS per °C (within the temperature compensation range)
- Weight
≈ 900g
- Protection
Standard:IP65
Flameproof: IP66
Intrinsically safe: IP65
Dust intrinsically safe : IP66
- Power
Current type ≤ 0.02 Us (W)
Digital type ≤ 0.015 Us (W)
Voltage type ≤ 0.008 Us (W)
Note: Us = Power Supply
- Load Characteristics
Current type load ≤ {((Us – 7.5) ÷ 0.02) (Us = Power Supply)} Ω
Voltage type load ≥ 100 kΩ
?
xxxxx
Item #2
Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.
Item #3
Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.
Item #4
Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.
Item #5
Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.